Key points
- Isolation is chosen for safety and ground separation, not as a default.
- Fixed losses explain why efficiency falls at light load.
- Derating trades output power for lower temperature and longer life.
- Ripple, saturation current and hold-up time each need a defined measurement or margin.
These are questions that engineers and students ask often when they begin designing with power converters. The answers are short and general. Where a topic has its own page, a link is given.
Should a converter be isolated or non-isolated?
Isolation is needed when safety rules require separation between circuits, when ground loops must be broken, or when the input and output sit at different potentials. If neither applies, a non-isolated converter is usually smaller, cheaper and more efficient. A common arrangement uses one isolated stage, then non-isolated converters near each load.
Why does efficiency fall at light load?
Some losses do not depend on output current: gate drive, controller supply current, core loss and switching loss per cycle. At full load they are small compared with the power delivered, but at light load they become a large fraction of it. Many converters therefore switch less often or skip pulses at light load to recover some efficiency.
What is point of load?
Point of load means a converter placed next to the device it powers, such as a processor. Short, wide connections lose little voltage and respond quickly to current steps. It is usually a non-isolated converter fed from a higher intermediate bus.
Why must a converter be derated?
Output power is limited by how much heat the parts can tolerate. As ambient temperature rises, or airflow falls, the temperature rise allowed by the parts is used up sooner, so the permitted output falls. Operating below the limit also lengthens life, because component stress drives most wear-out mechanisms.
What is galvanic isolation?
Galvanic isolation means there is no direct conductive path between two circuits. Energy passes through a transformer, and signals pass through an optocoupler or similar barrier. It prevents dangerous voltages from reaching the user and stops unwanted currents flowing between grounds.
How is an inductor chosen?
Start from the required inductance and the ripple current that is acceptable. Then check that the saturation current exceeds the peak current with margin, and that the RMS current is within the rating. Winding resistance sets conductive loss, and shielded types reduce stray fields. The application notes describe the steps in more detail.
What does a safety approval cover?
An approval states that a product was assessed against a particular safety standard under defined conditions. It usually does not guarantee performance, and a component approval does not automatically approve the equipment it is used in. The safety page explains the idea.
How do linear and switching regulators compare?
A linear regulator is simple, quiet and fast, but it can only step voltage down and wastes the difference as heat. A switching regulator can step up, step down or invert, and is much more efficient when the voltage difference is large, at the cost of switching noise and more parts.
What is ripple?
Ripple is the small alternating component left on a DC output after filtering. It occurs at the switching frequency and its harmonics, and is usually quoted as a peak-to-peak value measured with a short ground connection and limited bandwidth.
What is hold-up time?
Hold-up time is how long the output stays within its limits after the input is lost. It depends on the energy stored in the input capacitors and on how low the converter can take its input voltage before dropping out.
How much margin should a design leave?
There is no single figure, because the right margin depends on the cost of failure and on how well the operating conditions are known. A common habit is to keep output current and temperature comfortably below the rated limits, and to check the lowest input voltage and the highest ambient temperature together, since the worst case is usually the combination.
Can converters be connected in series or parallel?
Series connection of outputs is sometimes allowed, but the datasheet must say so. Parallel connection needs a current-sharing method, because small differences in output voltage make one unit carry most of the load. The application notes discuss this further.