Key points
- Processor and DSP core voltages fell while currents rose, making distribution losses and accuracy more important.
- Intermediate bus architectures paired one isolated stage with several non-isolated converters.
- Tighter voltage tolerances and fast load steps raised the demands on regulators and capacitance.
- Interest in digital control grew as a way to add monitoring and flexibility.
This archive entry is a topic note about what was changing in power conversion between 2003 and 2005. It is not a list of announcements. One of the clearest trends in that period was the movement of conversion closer to the devices that consume the power.
Falling voltages, rising currents
Each new generation of processors, digital signal processors and programmable logic used a lower core voltage than the one before, while the current they drew went up. For a given power, halving the voltage doubles the current, and the voltage lost in board copper rises with that current. A tolerance of a few per cent on a core rail of about one volt leaves only a few tens of millivolts for all errors together, including regulation, ripple and the drop in the wiring.
Intermediate bus architectures
A common response was the intermediate bus architecture. A single isolated converter produced a moderate bus voltage on the board, and several small non-isolated converters, placed beside their loads, stepped it down to each required rail. This reduced current on long routes, separated the isolation function from the regulation function and let designers add or change rails with less rework. The converter families page describes the isolated and non-isolated types involved.
Load steps and accuracy
Digital loads can change from light to heavy current in a very short time. The regulator and the output capacitors together must hold the voltage inside its window during that step. This led designers to use higher switching frequencies, lower-impedance capacitors and careful layout. An example application, powering several rails for programmable logic, is worked through in the application notes.
Interest in digital control
Toward the end of the period, digital control of power converters attracted growing interest. A digital controller can adjust compensation, report status and manage sequencing through a communication interface, at the cost of added complexity and cost. Whether it paid off depended strongly on the application, and analogue control remained the usual choice for simple rails.