Five short design notes on common power problems: FPGA rails, input filtering, thermal derating, paralleling and inductor selection.

Key points

  • FPGA rails need attention to sequencing, ripple and fast load steps as much as to average current.
  • Input filters reduce conducted noise, and common mode and differential mode noise need different cures.
  • Output power must be derated as ambient temperature rises, using the maker's curve.
  • Plain paralleling of converters risks unequal sharing, so use a defined sharing method.
  • Inductor selection balances inductance, saturation current, RMS current, resistance and shielding.

These notes are short, general design guides. They explain what to think about and why, with round illustrative numbers rather than data. Always check the maker's current datasheet for the part in use.

Choosing a converter for FPGA power rails

A programmable logic device usually needs several supplies: a core rail, one or more input and output rails and sometimes an auxiliary or transceiver rail. Each has its own voltage, tolerance and current, and the core voltage tends to be the lowest and the most demanding. A core rail of about 1 V may need an accuracy of a few percent, including ripple and load transients.

Check three things first. The first is sequencing: many devices specify that rails come up in a certain order or within a set time. A converter with an enable pin or a tracking input makes this simple. The second is ripple and noise, which eat into the tolerance budget. The third is the current step: a design that switches thousands of logic elements can change its current demand quickly, so the converter and its output capacitors must hold the voltage through the step. Non-isolated point-of-load converters, covered in the point-of-load note, suit this job well.

Input filtering and EMI

A switching converter draws pulsed current from its source, and that pulsing becomes conducted noise on the input lines. Regulations limit this noise, and it can also disturb other circuits on the same supply. The usual remedy is an LC filter at the input: a series inductor and a shunt capacitor that together attenuate noise above their corner frequency.

Noise travels in two forms. Differential mode noise flows out on one line and back on the other, and a series inductor with a shunt capacitor treats it. Common mode noise flows on both lines together and returns through ground or stray capacitance, and it is treated with a common mode choke and capacitors to ground. Ferrite beads and cores add loss at high frequencies. One caution applies: a filter placed before a converter has its own output impedance, and a poorly damped filter can interact with the converter's negative input resistance and cause instability. Layout matters as much as the filter values.

Thermal derating basics

No converter is perfectly efficient, so some power always becomes heat. The internal temperature depends on ambient temperature, airflow, the heat conducted into the board and the power lost. To keep internal parts inside their limits, the maximum output power must fall as ambient temperature rises above a stated point. This reduction is called derating.

The maker usually publishes a derating curve, with ambient temperature on the horizontal axis and allowable output power or current on the vertical axis, often with separate lines for different airflow speeds. To use it, find the highest ambient temperature the equipment will see at the converter, read the allowable output at that temperature and airflow, and compare it with the load. Leave margin. Running parts cooler also tends to extend their life, which is one reason designers derate even when the datasheet would allow more.

Paralleling converters

Designers parallel converters either to obtain more current than one unit can supply, or to add redundancy so the load survives a failure. Simply wiring two outputs together is risky. Two regulators with slightly different setpoints fight each other: the unit with the higher voltage carries most or all of the load while the other carries little, so the stressed unit runs hotter and the benefit is lost.

The sound approach is a defined current sharing method. Some converters include a share pin that lets units balance their currents, while others use a deliberate droop in output voltage so the load divides naturally. For redundancy, place an ORing diode, or an ideal-diode controller, in each output path so that a failed unit cannot pull the common bus down or be driven backwards. The diode costs some voltage and efficiency, so allow for it in the design.

Inductor selection

For a buck converter, the inductance sets the ripple current. A common starting point is a ripple current of roughly 20 to 40 percent of the maximum load current. A larger inductance lowers ripple but increases size, cost and the time the current takes to respond to a load change.

Several ratings matter. Saturation current is the current at which the core's permeability collapses and inductance falls by a stated amount, often 20 to 30 percent; the peak current, including ripple, must stay below it. RMS current or heating current sets the temperature rise. DCR, the winding resistance, causes conduction loss, so lower is better for efficiency. Shielding contains the magnetic field and reduces coupling into nearby circuits, at some cost in size and price. See the overview of magnetics for the wider context.

Continue reading