CD Power Online
Home/Converters/Reading a datasheet

Converters

How to read a converter datasheet

The key datasheet parameters for DC/DC converters, what each one means, and a short method for narrowing a choice.

Key points

  • Start from the hard constraints: input range, output voltage, current and isolation requirement.
  • Efficiency varies with load, so read the curve at the load the design actually runs at.
  • Ripple and noise figures depend on the measurement method and bandwidth.
  • MTBF figures are statistical estimates and are not a guarantee of life.

A datasheet lists dozens of numbers, but a handful decide whether a converter fits. This note explains them and then gives a short order of work for narrowing a choice. The wider range of parts is described in the converter families.

Electrical parameters

The input voltage range must cover the lowest and highest voltage the source can produce, including tolerance and transients. Output voltage and output current define the load the converter can serve. Line regulation is how much the output changes when the input moves across its range, and load regulation is how much it changes when the load moves from light to full. Both are usually quoted as a percentage of the nominal output.

Efficiency is output power divided by input power, and it changes with load. Many converters are most efficient between about half and full load and lose efficiency at light load, where fixed losses dominate. Read the efficiency curve at the load you expect, not only the peak figure. Ripple and noise describe the unwanted ac component on the output. The value depends on how it was measured, in particular the bandwidth and the probe technique, so compare like with like.

Isolation, temperature and size

The isolation rating is the voltage the barrier between input and output is tested to, and it says nothing by itself about what the end product needs. The operating temperature range tells you the ambient limits, but the derating curve shows how much output is available as the temperature rises. Switching frequency influences the size of the magnetics and the filter needed, and it affects where noise appears in the spectrum. Footprint and height set whether the part fits the board and the airflow path.

Protection and reliability

Look for protection features: short circuit protection, over-temperature shutdown, and under-voltage lockout, which holds the converter off until the input is high enough to start cleanly. Also check how the converter behaves after a fault, whether it latches off or retries.

A published MTBF, mean time between failures, is a statistical estimate calculated from a model or from test data. It is not a prediction of the life of one unit, and different calculation methods give different numbers, so comparing MTBF between datasheets only works when the method and temperature are the same.

A short method for narrowing choices

  1. List the fixed requirements: input range, output voltage, output current with margin, and whether isolation is needed.
  2. Remove anything that cannot meet the temperature and derating need at the real ambient.
  3. Check efficiency at the actual load, then the thermal result it implies.
  4. Compare ripple, noise and regulation against what the load tolerates.
  5. Choose among what remains by footprint, protection features and ease of sourcing.

Approvals matter for the final product too, and the safety approvals note explains the general ideas.

Continue reading